| F1682-02 Standard Test Method for Determining Travel of a Membrane Switch |
| This test method covers the determination of the travel of a membrane switch. |
|
|
| F1597-02 Standard Test Method for Determining the Actuation Force and Contact Force of a Membrane Switch |
| This test method covers the measurement of actuation force or contact force, or both, of a membrane switch utilizing a pre-determined resistance value.
|
|
|
| F1570-01e1 Standard Test Method for Determining the Tactile Ratio of a Membrane Switch |
| This test method covers the determination of the tactile response of a membrane switch as defined by tactile ratio.
|
|
|
| F1896-98 Test Method for Determining the Electrical Resistivity of a Printed Conductive Material |
- This test method covers the determination of the electrical resistivity of
a conductive material as used in the manufacture of a membrane switch.
- This test method is not suitable for measuring force sensitive conductive
materials.
- The values stated in inch-pound units are to be regarded as the standard.
The values given in parentheses are for information only.
|
|
|
| F1812-02 Standard Test Method for Determining the Effectiveness of Membrane Switch ESD Shielding |
| This test method is used to determine the electrostatic discharge (ESD) shielding effectiveness of a membrane switch assembly. This test method may be used to test a membrane switch to destruction, that is, to determine its maximum ESD shielding effectiveness, or it may be used to test the ability of a membrane switch to withstand a predetermined level of exposure.
|
|
|
| F1689-05 Standard Test Method for Determining the Insulation Resistance of a Membrane Switch |
| This test method covers the determination of the insulation resistance of a membrane switch.
|
|
|
| F1681-96 Standard Test Method for Determining Current Carrying Capacity of a Conductor as Part of a Membrane Switch Circuit |
|
This test method covers the determination of the current carrying capacity of
a conductor as part of a membrane switch.
This test method may be used to test a circuit to destruction, that is, to
determine its maximum current carrying capacity, or it may be used to test the
ability of a circuit to withstand a desired current level.
This test method applies only to static conditions, and does not apply to
contact closure cycling of a membrane switch under current load (test method
forthcoming).
|
|
|
| F1680-02 Standard Test Method for Determining Circuit Resistance of a Membrane Switch |
| This test method covers the determination of the circuit resistance of a membrane switch utilizing a predetermined force.
|
|
|
|