Tube / Pipe Circumference Weld Joint Calculation

[ Weld Design Menu ] [ Product and Services Directory ]

Normal Stress in Weld Base Area

Where:

= Normal stress [MPa,psi]

FZ

= Applied axial force  [N, lb]

A

= Throat are of weld [mm2,in2]

Comparative Stress 

Where:

= Comparative stress [MPa,psi]
= Normal stress  [MPa,psi]
= Conversion coefficient of weld joint 